- Remove --mode, --transition-type, and --decay-index CLI flags
(parameters now come from ENSDF data or custom JSON input)
- Clarify energy units in all CLI help text (MeV throughout, keV for detector params)
- Enhance logging verbosity:
- -v (INFO): shows source, component initialization, workflow steps
- -vv (DEBUG): shows detailed internals of all spectrum components
(parameters, evaluation counts, input/output ranges)
- Improve CSV headers with element notation (e.g. Tc99 -> Ru99)
- Add CONVENTIONS.md documenting energy unit and logging conventions
- Update TODO.md with completion status
162 lines
5.6 KiB
Markdown
162 lines
5.6 KiB
Markdown
# Project Conventions
|
|
|
|
This file defines the physical, mathematical, and architectural conventions that govern code correctness and consistency across the project.
|
|
|
|
## 1. Natural Units System
|
|
|
|
All internal representations, calculations, and definitions use natural units:
|
|
|
|
```
|
|
m_e = ℏ = c = 1
|
|
```
|
|
|
|
where `m_e` is the electron rest mass. This is the fundamental unit for energy, mass, momentum, and time throughout the codebase.
|
|
|
|
## 2. Energy Representation
|
|
|
|
### Core Principle
|
|
|
|
Internal calculations use natural units (m_e). External interfaces (API signatures, plots, human-readable output) use eV-based units (MeV or keV).
|
|
|
|
### API Signatures (Input)
|
|
|
|
Use human-readable MeV for parameters that come from databases or literature:
|
|
|
|
- `endpoint_MeV` — Q-value / endpoint energy in MeV
|
|
- `detector_sigma_a_keV` — resolution in keV
|
|
- `detector_tau_keV` — tail decay constant in keV
|
|
|
|
### Internal Representation
|
|
|
|
All internal computations use **total energy W in m_e units**:
|
|
|
|
```
|
|
W = T_to_W(T_MeV) # T (kinetic) in MeV → W (total) in m_e
|
|
W = T + 1.0 # W = T/m_e + 1 (since m_e = 1 in m_e units)
|
|
```
|
|
|
|
- `W = 1.0` corresponds to zero kinetic energy (rest mass)
|
|
- `W > 1.0` corresponds to kinetic energy
|
|
- All internal functions accept and operate on `W`
|
|
- Endpoint W0 is always `T_to_W(endpoint_MeV)`
|
|
|
|
### Output and Display
|
|
|
|
Convert back to eV units for anything intended for human perception:
|
|
|
|
- Plots: x-axis in keV or MeV (kinetic energy)
|
|
- ASCII output, CSV export: kinetic energy in keV or MeV
|
|
- Log messages, error messages: use keV/MeV with context
|
|
|
|
```python
|
|
kinetic_keV = (W - 1.0) * ME_KEV # W in m_e → kinetic energy in keV
|
|
kinetic_MeV = (W - 1.0) * ME_ME # W in m_e → kinetic energy in MeV
|
|
```
|
|
|
|
### Conversion Helpers
|
|
|
|
All conversions and constants must go through the central utilities:
|
|
|
|
```python
|
|
from beta_spectrum.utils import T_to_W, W_to_T
|
|
from beta_spectrum.constants import ME_MEV, ME_KEV, ALPHA, MP_MEV
|
|
```
|
|
|
|
- Never hardcode physical constants — import from `constants.py`
|
|
- Never use manual arithmetic for unit conversion — use `T_to_W()`, `W_to_T()`
|
|
- Never mix MeV and m_e units in the same calculation
|
|
|
|
## 3. Energy Unit Convention
|
|
|
|
### MeV Throughout
|
|
|
|
All energy parameters in the public API use **MeV** as the standard unit:
|
|
|
|
- `endpoint_MeV` — always in MeV
|
|
- `e_step_MeV` — always in MeV
|
|
- `detector_sigma_a_keV` — in keV (detector-specific, exception noted)
|
|
- `detector_tau_keV` — in keV (detector-specific, exception noted)
|
|
|
|
Detector parameters use keV because detector resolutions are typically specified in keV in the literature. All other energies use MeV.
|
|
|
|
### CLI Unit Convention
|
|
|
|
All CLI energy parameters use MeV unless explicitly marked otherwise:
|
|
|
|
- `--e-step` — MeV (default: 0.001)
|
|
- `--sigma` — keV (detector resolution, default: 1.0)
|
|
- `--tau` — keV (tail decay constant, default: 5.0)
|
|
|
|
### Consistency Rule
|
|
|
|
When reading or writing values, always check the unit suffix in the parameter name:
|
|
- `_MeV` suffix → value is in MeV
|
|
- `_keV` suffix → value is in keV
|
|
- No suffix on energy parameter → value is in m_e units (internal)
|
|
|
|
## 4. SpectrumComponent Design
|
|
|
|
All spectral components (Fermi function, screening, radiative correction, etc.) follow a common interface:
|
|
|
|
- **Stateless or minimally stateful** — no mutable state that depends on input
|
|
- **Vectorized** — accept and return `np.ndarray`, support array broadcasting
|
|
- **Consistent energy variable** — always use `W` (total energy in m_e units) internally
|
|
- **Callable interface** — implement `__call__(W)` for uniform usage
|
|
- **Return correction factor** — output is a multiplicative factor, typically ~0.1 to 10
|
|
|
|
```python
|
|
class MyComponent(SpectrumComponent):
|
|
def __init__(self, param1: float, param2: float):
|
|
self.param1 = param1
|
|
self.param2 = param2
|
|
|
|
def __call__(self, W: np.ndarray) -> np.ndarray:
|
|
# All internal computation uses W in m_e units
|
|
return ...
|
|
```
|
|
|
|
## 5. Logging Convention
|
|
|
|
### Verbosity Levels
|
|
|
|
- **No verbosity (default)**: Only errors and warnings
|
|
- **`-v` (INFO)**: Shows source selection, component initialization, workflow steps, and output locations
|
|
- **`-vv` (DEBUG)**: Shows all INFO messages plus detailed internals of each spectrum component (parameters, input/output ranges, evaluation counts)
|
|
|
|
### Component Logging
|
|
|
|
Each `SpectrumComponent` logs at two levels:
|
|
|
|
- **INFO** at initialization: Component name and key parameters
|
|
- **DEBUG** at evaluation: Number of energy points, input/output value ranges
|
|
|
|
This allows debugging without cluttering normal output.
|
|
|
|
## 6. Nuclear Data Notation
|
|
|
|
### Element and Nuclide Notation
|
|
|
|
- Element symbol: `Tc`, `Ru`, `U`, etc. (from atomic number)
|
|
- Nuclide notation: `Tc99`, `Ru99`, `U238` (element symbol + mass number)
|
|
- Decay notation: `Tc99 -> Ru99` (parent -> daughter)
|
|
|
|
### CSV Header Convention
|
|
|
|
CSV metadata headers use element notation for readability:
|
|
|
|
```
|
|
# nuclide: Tc99 -> Ru99 (Z=43->44)
|
|
```
|
|
|
|
This provides both the human-readable notation and the machine-parseable Z values.
|
|
|
|
## 7. Physics-Specific Testing Guidelines
|
|
|
|
When writing tests for physics components, verify the following:
|
|
|
|
- **Physical constraints** — values at thresholds, endpoints, and boundaries must match known physics behavior
|
|
- **Monotonicity / positivity** — spectrum components should not produce unphysical negative values; monotonicity should match physical expectations
|
|
- **Shape correctness** — output shape must match input shape (vectorized operation)
|
|
- **Type safety** — components accept and return `np.ndarray`
|
|
- **Numerical stability** — no NaN or inf in the physical energy range, except where physically expected (e.g., below kinematic threshold, near soft-photon endpoint divergence)
|