- Organize into tree structure: corrections/, nuclear-structure/, gA-extraction/, refs/ - Move all correction notes to corrections/ (01-09) - Move nuclear structure to nuclear-structure/ with index - Add gA-extraction/ with SSM algorithm, sNME/ESSM formalism, Tc99 case study, and implementation TODO - Reorganize refs by topic (electromagnetic/, forbidden-decay/) - Update all wikilinks to new paths - Remove radiative_spec.md (code algorithm, not reference) - Lint: all wikilinks verified valid - Comprehensive gA extraction research based on Paulsen et al. (2024) and Song et al. (2025)
4.5 KiB
title, date, tags, status, aliases, related_notes
| title | date | tags | status | aliases | related_notes | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| $^{99}$Tc Case Study — gA Extraction Results | 2026-05-14 |
|
active |
|
|
$^{99}$Tc — The Premier Laboratory for gA Extraction
Decay Properties
| Property | Value |
|---|---|
| Transition | ^{99}\text{Tc}(9/2_1^+) \to {}^{99}\text{Ru}(5/2_1^+) |
| Forbiddenness | Second-forbidden nonunique |
| Branching ratio | 99.99855(30)% |
| Q-value | 295.82(16) keV (Paulsen et al.) |
| Half-life | 211.5(1.1) \times 10^3 a (ENSDF) |
| Dominant transition | 2d_{5/2} \to 1g_{9/2} (OBTD \approx 0.478) |
| Sub-dominant | 1g_{7/2} \to 1g_{9/2} (OBTD \approx 0.010) |
Two Contradictory Results
Result 1: Paulsen et al. (2024) — Enhanced g_A
Measurement: MMC at PTB Berlin + LNHB Paris. Two independent setups, consistent results.
Method: Fixed sNME to CVC value (CloseCVC).
Result:
g_A^{\text{eff}} = 1.526(92)
This is an enhanced value — significantly above the free-nucleon value of 1.27.
Follow-on values:
g_V^{\text{eff}} = 0.376(5)— quenched (via half-life normalization)g_A^{\text{eff, quenched}} = 0.574(36)— quenched\bar{E}_\beta = 98.51(23)keV\log ft = 12.3478(23)
Key claim: This resolves an inconsistency — first-forbidden nonunique transitions show g_A^{\text{eff}} \approx 0.9, while fourth-forbidden show g_A^{\text{eff}} \approx 0.9. The ^{99}\text{Tc} result suggests g_A is enhanced in second-forbidden decays.
Result 2: Song et al. (2025) — Quenched g_A
Measurement: MMC at LLNL (KRISS sensor). Independent of Paulsen et al.
Method: ESSM — sNME fitted as free parameter (FarCVC).
Result:
g_A^{\text{eff}} \approx 1.0\text{--}1.2
This is a quenched value, consistent with first-forbidden and fourth-forbidden nonunique decays.
Best fit: glekpn Hamiltonian, g_A^{\text{eff}} = 1.2, sNME = −0.0698 fm³, \chi^2_\nu = 1.066, p-value = 0.22
Key claim: The Paulsen result is an artifact of fixing sNME to CVC. When sNME is fitted, the data prefer quenched g_A, consistent with the broader pattern.
The Crucial Difference: sNME Treatment
| Aspect | Paulsen et al. | Song et al. |
|---|---|---|
| sNME treatment | Fixed to CVC value | Fitted as free parameter (ESSM) |
g_A^{\text{eff}} |
1.526(92) (enhanced) | 1.0–1.2 (quenched) |
| Nuclear models | NSM (GLEKPN) only | NSM (glekpn, jj45pnb) + MQPM |
| Half-life constraint | Separate normalization | Simultaneous shape + half-life fit |
| Consistency with 113Cd, 115In | Inconsistent | Consistent |
What This Means for Your Experiment
The ^{99}\text{Tc} case demonstrates that the treatment of sNME is the dominant theoretical systematic in gA extraction. The two experiments (Paulsen and Song) measured essentially the same spectrum (Paulsen's data was used as input for Song's analysis) but obtained contradictory results because of different theoretical assumptions.
For your data analysis:
- Do not fix sNME to CVC — treat it as a fitting parameter
- Use ESSM — simultaneous fit to spectral shape + half-life
- Try multiple nuclear models — glekpn, jj45pnb, and MQPM (if available)
- Report both sNME solutions (c and f) for each model
- The "optimal" choice (closest to CVC) is theoretically motivated but requires experimental validation
Your Polynomial Fit: Connecting to SSM
You've fitted C(W) = A \cdot W + B \cdot W^{-1} + C \cdot W^2. This empirical parametrization can be cross-checked against the SSM prediction:
- Compute
C_{\text{SSM}}(W; g_A)for a range ofg_Avalues - Fit each SSM curve to the polynomial form
aW + bW^{-1} + cW^2over your fit range - Extract the effective
(A, B, C)as a function ofg_A - Compare your fitted
(A, B, C)to the $g_A$-dependent curve to identify whichg_Arange is consistent
This provides a model-independent bridge between your empirical fit and the physical g_A extraction.
References
| Ref | Citation |
|---|---|
| [Paulsen2024] | Paulsen et al., Phys. Rev. C 110, 055503 (2024) |
| [Song2025] | Song et al., arXiv:2506.17544 (2025) |
| [Kostensalo2017] | Kostensalo & Suhonen, Phys. Rev. C 96, 024317 (2017) |
| [ESSM] | Kumar et al., Eur. Phys. J. A 57, 225 (2021) |