# Project Conventions
|
||||
|
||||
This file defines the physical, mathematical, and architectural conventions that govern code correctness and consistency across the project.
|
||||
|
||||
## 1. Natural Units System
|
||||
|
||||
All internal representations, calculations, and definitions use natural units:
|
||||
|
||||
```
|
||||
m_e = ℏ = c = 1
|
||||
```
|
||||
|
||||
where `m_e` is the electron rest mass. This is the fundamental unit for energy, mass, momentum, and time throughout the codebase.
|
||||
|
||||
## 2. Energy Representation
|
||||
|
||||
### Core Principle
|
||||
|
||||
Internal calculations use natural units (m_e). External interfaces (API signatures, plots, human-readable output) use eV-based units (MeV or keV).
|
||||
|
||||
### API Signatures (Input)
|
||||
|
||||
Use human-readable MeV for parameters that come from databases or literature:
|
||||
|
||||
- `endpoint_MeV` — Q-value / endpoint energy in MeV
|
||||
- `detector_sigma_a_keV` — resolution in keV
|
||||
- `detector_tau_keV` — tail decay constant in keV
|
||||
|
||||
### Internal Representation
|
||||
|
||||
All internal computations use **total energy W in m_e units**:
|
||||
|
||||
```
|
||||
W = T_to_W(T_MeV) # T (kinetic) in MeV → W (total) in m_e
|
||||
W = T + 1.0 # W = T/m_e + 1 (since m_e = 1 in m_e units)
|
||||
```
|
||||
|
||||
- `W = 1.0` corresponds to zero kinetic energy (rest mass)
|
||||
- `W > 1.0` corresponds to kinetic energy
|
||||
- All internal functions accept and operate on `W`
|
||||
- Endpoint W0 is always `T_to_W(endpoint_MeV)`
|
||||
|
||||
### Output and Display
|
||||
|
||||
Convert back to eV units for anything intended for human perception:
|
||||
|
||||
- Plots: x-axis in keV or MeV (kinetic energy)
|
||||
- ASCII output, CSV export: kinetic energy in keV or MeV
|
||||
- Log messages, error messages: use keV/MeV with context
|
||||
|
||||
```python
|
||||
kinetic_keV = (W - 1.0) * ME_KEV # W in m_e → kinetic energy in keV
|
||||
kinetic_MeV = (W - 1.0) * ME_ME # W in m_e → kinetic energy in MeV
|
||||
```
|
||||
|
||||
### Conversion Helpers
|
||||
|
||||
All conversions and constants must go through the central utilities:
|
||||
|
||||
```python
|
||||
from beta_spectrum.utils import T_to_W, W_to_T
|
||||
from beta_spectrum.constants import ME_ME, ME_KEV, ALPHA, M_P
|
||||
```
|
||||
|
||||
- Never hardcode physical constants — import from `constants.py`
|
||||
- Never use manual arithmetic for unit conversion — use `T_to_W()`, `W_to_T()`
|
||||
- Never mix MeV and m_e units in the same calculation
|
||||
|
||||
## 3. SpectrumComponent Design
|
||||
|
||||
All spectral components (Fermi function, screening, radiative correction, etc.) follow a common interface:
|
||||
|
||||
- **Stateless or minimally stateful** — no mutable state that depends on input
|
||||
- **Vectorized** — accept and return `np.ndarray`, support array broadcasting
|
||||
- **Consistent energy variable** — always use `W` (total energy in m_e units) internally
|
||||
- **Callable interface** — implement `__call__(W)` for uniform usage
|
||||
- **Return correction factor** — output is a multiplicative factor, typically ~0.1 to 10
|
||||
|
||||
```python
|
||||
class MyComponent(SpectrumComponent):
|
||||
def __init__(self, param1: float, param2: float):
|
||||
self.param1 = param1
|
||||
self.param2 = param2
|
||||
|
||||
def __call__(self, W: np.ndarray) -> np.ndarray:
|
||||
# All internal computation uses W in m_e units
|
||||
return ...
|
||||
```
|
||||
|
||||
## 4. Physics-Specific Testing Guidelines
|
||||
|
||||
When writing tests for physics components, verify the following:
|
||||
|
||||
- **Physical constraints** — values at thresholds, endpoints, and boundaries must match known physics behavior
|
||||
- **Monotonicity / positivity** — spectrum components should not produce unphysical negative values; monotonicity should match physical expectations
|
||||
- **Shape correctness** — output shape must match input shape (vectorized operation)
|
||||
- **Type safety** — components accept and return `np.ndarray`
|
||||
- **Numerical stability** — no NaN or inf in the physical energy range, except where physically expected (e.g., below kinematic threshold, near soft-photon endpoint divergence)
|
||||
+3
-5
@@ -57,11 +57,9 @@ Branch naming: `dev/<short-description>` (e.g., `dev/recoil-correction`)
|
||||
|
||||
### What to Test
|
||||
|
||||
- **Physical constraints**: values at thresholds, endpoints, and boundaries must match known physics
|
||||
- **Monotonicity / positivity**: spectrum components should not produce unphysical negative values
|
||||
- **Shape correctness**: output shape must match input shape
|
||||
- **Type safety**: components accept and return `np.ndarray`
|
||||
- **Numerical stability**: no NaN or inf in the physical energy range (except where physically expected)
|
||||
See [`CONVENTIONS.md`](CONVENTIONS.md) §4 for physics-specific testing guidelines (physical constraints, positivity, numerical stability).
|
||||
|
||||
For general test structure, use the conventions below.
|
||||
|
||||
## 4. Quality Gates
|
||||
|
||||
|
||||
Reference in New Issue
Block a user